#include <HcalTimeSlew.h>
Public Types | |
enum | BiasSetting { Slow =0, Medium =1, Fast =2 } |
Static Public Member Functions | |
static double | delay (double fC, BiasSetting bias=Medium) |
Returns the amount (ns) by which a pulse of the given number of fC will be delayed by the timeslew effect, for the specified bias setting. More... | |
Provides pulse delay as a function of amplitude for three choices of QIE bias setting. The "Medium" setting is used in HB and HE, while the "Slow" (and lower noise) setting is used in HO. All data taken from bench measurements of the QIE and plotted in Physics TDR Vol 1.
Not to be used for HF at this time (unlikely to have much effect, however)
Definition at line 17 of file HcalTimeSlew.h.
Enumerator | |
---|---|
Slow | |
Medium | |
Fast |
Definition at line 19 of file HcalTimeSlew.h.
|
static |
Returns the amount (ns) by which a pulse of the given number of fC will be delayed by the timeslew effect, for the specified bias setting.
Definition at line 8 of file HcalTimeSlew.cc.
References log, slope, tmax, and tzero.
Referenced by HcalPulseContainmentAlgo::calcpair(), HcalTimeSlewSim::delay(), HcalHitCorrection::delay(), and HcalSimpleRecAlgoImpl::reco().