CMS 3D CMS Logo

 All Classes Namespaces Files Functions Variables Typedefs Enumerations Enumerator Properties Friends Macros Groups Pages
Variables
SiStripClientConfig_Tier0_HeavyIons_cff Namespace Reference

Variables

tuple mergedSiStripQualityProducer
 
tuple siStripOfflineAnalyser
 
tuple SiStripOfflineDQMClientHI = cms.Sequence(siStripQTesterHI*siStripOfflineAnalyser*siStripBadComponentInfo)
 
tuple siStripQTesterHI
 

Variable Documentation

tuple SiStripClientConfig_Tier0_HeavyIons_cff.mergedSiStripQualityProducer
Initial value:
1 = siStripQualityESProducer.clone(
2  #names and desigantions
3  ListOfRecordToMerge = cms.VPSet(
4  cms.PSet(record = cms.string("SiStripDetVOffRcd"), tag = cms.string('')), # DCS information
5  cms.PSet(record = cms.string('SiStripDetCablingRcd'), tag = cms.string('')), # Use Detector cabling information to exclude detectors not connected
6  cms.PSet(record = cms.string('SiStripBadChannelRcd'), tag = cms.string('')), # Online Bad components
7  cms.PSet(record = cms.string('SiStripBadFiberRcd'), tag = cms.string('')), # Bad Channel list from the selected IOV as done at PCL
8  # BadChannel list from FED errors is included below
9  cms.PSet(record = cms.string('RunInfoRcd'), tag = cms.string('')) # List of FEDs exluded during data taking
10  ),
11  ReduceGranularity = False,
12  ThresholdForReducedGranularity = 0.3,
13  appendToDataLabel = 'MergedBadComponent'
14 )

Definition at line 37 of file SiStripClientConfig_Tier0_HeavyIons_cff.py.

tuple SiStripClientConfig_Tier0_HeavyIons_cff.siStripOfflineAnalyser
Initial value:
1 = cms.EDProducer("SiStripOfflineDQM",
2  GlobalStatusFilling = cms.untracked.int32(2),
3  CreateSummary = cms.untracked.bool(False),
4  SummaryConfigPath = cms.untracked.string("DQM/SiStripMonitorClient/data/sistrip_monitorelement_config.xml"),
5  UsedWithEDMtoMEConverter = cms.untracked.bool(True),
6  PrintFaultyModuleList = cms.untracked.bool(True),
7  CreateTkMap = cms.untracked.bool(False),
8  TrackRatePSet = cms.PSet(
9  Name = cms.string("NumberOfTracks_"),
10  LowerCut = cms.double(0.0),
11  UpperCut = cms.double(1000.0),
12  ),
13  TrackChi2PSet = cms.PSet(
14  Name = cms.string("Chi2oNDF_"),
15  LowerCut = cms.double(0.0),
16  UpperCut = cms.double(25.0),
17  ),
18  TrackHitPSet = cms.PSet(
19  Name = cms.string("NumberOfRecHitsPerTrack_"),
20  LowerCut = cms.double(3.0),
21  UpperCut = cms.double(30.0),
22  )
23 )

Definition at line 4 of file SiStripClientConfig_Tier0_HeavyIons_cff.py.

tuple SiStripClientConfig_Tier0_HeavyIons_cff.SiStripOfflineDQMClientHI = cms.Sequence(siStripQTesterHI*siStripOfflineAnalyser*siStripBadComponentInfo)

Definition at line 59 of file SiStripClientConfig_Tier0_HeavyIons_cff.py.

tuple SiStripClientConfig_Tier0_HeavyIons_cff.siStripQTesterHI
Initial value:
2  qtList = cms.untracked.FileInPath('DQM/SiStripMonitorClient/data/sistrip_qualitytest_config_tier0_heavyions.xml'),
3  prescaleFactor = cms.untracked.int32(1),
4  getQualityTestsFromFile = cms.untracked.bool(True)
5 )

Definition at line 30 of file SiStripClientConfig_Tier0_HeavyIons_cff.py.