1 import FWCore.ParameterSet.Config as cms
2 
5 
6 from L1Trigger.L1TCalorimeter.caloParams_cfi import caloParamsSource
7 import L1Trigger.L1TCalorimeter.caloParams_cfi
8 #caloStage1ParamsSource = L1Trigger.L1TCalorimeter.caloParams_cfi.caloParamsSource.clone()
9 caloStage1Params = L1Trigger.L1TCalorimeter.caloParams_cfi.caloParams.clone()
10 
11 caloStage1Params.regionPUSType = cms.string("PUM0") #"None" for no PU subtraction, "PUM0", "HICaloRingSub"
12 caloStage1Params.regionPUSParams = regionSubtraction_PU40_MC13TeV
13 
14 # EG
15 caloStage1Params.egLsb = cms.double(1.)
16 caloStage1Params.egSeedThreshold = cms.double(0.)
17 
18 caloStage1Params.egMinPtJetIsolation = cms.int32(25)
19 caloStage1Params.egMaxPtJetIsolation = cms.int32(63)
20 caloStage1Params.egMinPtHOverEIsolation = cms.int32(1)
21 caloStage1Params.egMaxPtHOverEIsolation = cms.int32(40)
22 
23 caloStage1Params.egPUSType = cms.string("None")
24 caloStage1Params.egPUSParams = cms.vdouble()
25 
26 ## EG Isolation LUT
27 ## caloStage1Params.egIsoLUTFile = cms.FileInPath("L1Trigger/L1TCalorimeter/data/egIsoLUT_stage1.txt")
28 caloStage1Params.egIsoLUTFile = cms.FileInPath("L1Trigger/L1TCalorimeter/data/egIsoLUT_stage1_isolEB0.30_isolEE0.50_combined.txt")
29 #caloStage1Params.egIsoLUTFileBarrel = cms.FileInPath("L1Trigger/L1TCalorimeter/data/egIsoLUT_stage1_isol0.30.txt")
30 #caloStage1Params.egIsoLUTFileEndcaps = cms.FileInPath("L1Trigger/L1TCalorimeter/data/egIsoLUT_stage1_isol0.50.txt")
31 
32 # Tau
33 caloStage1Params.tauSeedThreshold = cms.double(7.)
34 caloStage1Params.tauNeighbourThreshold = cms.double(0.)
35 #Tau parameters below are only used for setting tau isolation flag
36 caloStage1Params.tauMaxPtTauVeto = cms.double(64.)
37 caloStage1Params.tauMinPtJetIsolationB = cms.double(192.)
38 caloStage1Params.tauMaxJetIsolationB = cms.double(100.)
39 caloStage1Params.tauMaxJetIsolationA = cms.double(0.1)
40 caloStage1Params.tauIsoLUTFile = cms.FileInPath("L1Trigger/L1TCalorimeter/data/tauIsoLUT_stage1_isolA0.10_isolB100.00_ch_switchToIsoBPt192.00_j8t8.txt")
41 ## caloStage1Params.tauCalibrationLUTFile = cms.FileInPath("L1Trigger/L1TCalorimeter/data/tauCalibrationLUT_stage1.txt")
42 caloStage1Params.tauCalibrationLUTFile = cms.FileInPath("L1Trigger/L1TCalorimeter/data/tauL1Calib_LUT.txt")
43 caloStage1Params.tauEtToHFRingEtLUTFile= cms.FileInPath("L1Trigger/L1TCalorimeter/data/tauHwEtToHFRingScale_LUT.txt")
44 caloStage1Params.isoTauEtaMin = cms.int32(5)
45 caloStage1Params.isoTauEtaMax = cms.int32(16)
46 # jets
47 caloStage1Params.jetLsb = cms.double(0.5)
48 caloStage1Params.jetSeedThreshold = cms.double(5.)
49 caloStage1Params.jetNeighbourThreshold = cms.double(0.)
50 caloStage1Params.jetCalibrationType = cms.string("Stage1JEC")
51 caloStage1Params.jetCalibrationParams = jetSF_8TeV_data
52 ## caloStage1Params.jetCalibrationLUTFile = cms.FileInPath("L1Trigger/L1TCalorimeter/data/jetCalibrationLUT_stage1_prelim.txt")
53 caloStage1Params.jetCalibrationLUTFile = cms.FileInPath("L1Trigger/L1TCalorimeter/data/jetCalibrationLUT_symmetric_0is0.txt")
54 
55 # sums
56 caloStage1Params.etSumLsb = cms.double(0.5)
57 caloStage1Params.etSumEtaMin = cms.vint32(4, 4) #ET, HT
58 caloStage1Params.etSumEtaMax = cms.vint32(17, 17) #ET, HT
59 caloStage1Params.etSumEtThreshold = cms.vdouble(0., 7.) #ET, HT
60 
61 # HI
62 caloStage1Params.minimumBiasThresholds = cms.vint32(3,3,6,6)
63 caloStage1Params.centralityLUTFile = cms.FileInPath("L1Trigger/L1TCalorimeter/data/centrality_extended_LUT_preRun.txt")
64 caloStage1Params.q2LUTFile = cms.FileInPath("L1Trigger/L1TCalorimeter/data/q2LUT_stage1.txt")