CMS 3D CMS Logo

CalibrationSummaryClient_cfi.py
Go to the documentation of this file.
1 import FWCore.ParameterSet.Config as cms
2 
3 from DQM.EcalMonitorClient.PNIntegrityClient_cfi import ecalPNIntegrityClient
4 from DQM.EcalMonitorClient.LaserClient_cfi import ecalLaserClient
5 from DQM.EcalMonitorClient.LedClient_cfi import ecalLedClient
6 from DQM.EcalMonitorClient.TestPulseClient_cfi import ecalTestPulseClient
7 from DQM.EcalMonitorClient.PedestalClient_cfi import ecalPedestalClient
8 
10 
11 activeSources = ['Laser', 'Led']
12 
13 ecalCalibrationSummaryClient = cms.untracked.PSet(
14  params = cms.untracked.PSet(
15  laserWavelengths = ecaldqmLaserWavelengths,
16  ledWavelengths = ecaldqmLedWavelengths,
17  testPulseMGPAGains = ecaldqmMGPAGains,
18  testPulseMGPAGainsPN = ecaldqmMGPAGainsPN,
19  pedestalMGPAGains = ecaldqmMGPAGains,
20  pedestalMGPAGainsPN = ecaldqmMGPAGainsPN,
21  activeSources = cms.untracked.vstring(activeSources),
22  ),
23  sources = cms.untracked.PSet(
24  Laser = ecalLaserClient.MEs.QualitySummary,
25  LaserPN = ecalLaserClient.MEs.PNQualitySummary,
26  Led = ecalLedClient.MEs.QualitySummary,
27  LedPN = ecalLedClient.MEs.PNQualitySummary,
28  Pedestal = ecalPedestalClient.MEs.QualitySummary,
29  PedestalPN = ecalPedestalClient.MEs.PNQualitySummary,
30  PNIntegrity = ecalPNIntegrityClient.MEs.QualitySummary,
31  TestPulse = ecalTestPulseClient.MEs.QualitySummary,
32  TestPulsePN = ecalTestPulseClient.MEs.PNQualitySummary
33  ),
34  MEs = cms.untracked.PSet(
35  PNQualitySummary = cms.untracked.PSet(
36  path = cms.untracked.string('%(subdet)s/%(prefix)sSummaryClient/%(prefix)s PN global quality'),
37  kind = cms.untracked.string('TH2F'),
38  otype = cms.untracked.string('MEM2P'),
39  btype = cms.untracked.string('Crystal'),
40  description = cms.untracked.string('Summary of the calibration data quality for the PN diodes. Channel is red if it is red in any of the Laser 3, Led 1 and 2, Pedestal gain 12, and Test Pulse gain 12 quality summary.')
41  ),
42  QualitySummary = cms.untracked.PSet(
43  path = cms.untracked.string('%(subdet)s/%(prefix)sSummaryClient/%(prefix)s global calibration quality%(suffix)s'),
44  kind = cms.untracked.string('TH2F'),
45  otype = cms.untracked.string('Ecal3P'),
46  btype = cms.untracked.string('SuperCrystal'),
47  description = cms.untracked.string('Summary of the calibration data quality. Channel is red if it is red in any of the Laser 3, Led 1 and 2, Pedestal gain 12, and Test Pulse gain 12 quality summary.')
48  )
49  )
50 )
CommonParams_cfi