RecoLocalCalo
HcalRecProducers
python
HBHEMethod0Parameters_cfi.py
Go to the documentation of this file.
1
import
FWCore.ParameterSet.Config
as
cms
2
3
# Behavior of "Method 0" depends on the following top-level
4
# HBHEPhase1Reconstructor parameters:
5
#
6
# (bool) tsFromDB
7
# (bool) recoParamsFromDB
8
#
9
# and on the following parameters inside the "algorithm" parameter set,
10
# defined as m0Parameters below:
11
#
12
# (int) firstSampleShift
13
# (int) samplesToAdd
14
# (bool) correctForPhaseContainment
15
# (double) correctionPhaseNS
16
#
17
# The role of "tsFromDB" parameter is to specify whether the
18
# "sample of interest" (SOI) should be taken from the data frame
19
# (in case tsFromDB is False) or from the database (tsFromDB is True).
20
# Once SOI is determined in this manner, the time slice for starting
21
# the ADC charge summation (TSS) is determined by adding SOI and
22
# "firstSampleShift". "firstSampleShift" can be negative, and if
23
# TSS = SOI + firstSampleShift ends up negative, TSS is reset to 0.
24
# If you want to start summation from time slice 0, just set
25
# "firstSampleShift" to some negative number with large magnitude.
26
#
27
# In the old reco code, it used to be possible to configure the TSS
28
# using a parameter value. This is no longer the case for Phase 1
29
# reconstructor.
30
#
31
# The values of the remaining M0 parameters, "samplesToAdd",
32
# "correctForPhaseContainment", and "correctionPhaseNS", will be
33
# taken from the configuration file only if "recoParamsFromDB"
34
# is set to False. If "recoParamsFromDB" is True, the config
35
# file values of these parameters are ignored, and these values
36
# are instead taken from the database. The "samplesToAdd" parameter
37
# defines how many contiguous time slices will be used to calculate
38
# the charge. TSS + samplesToAdd should not exceed the number of
39
# time slices in the data frame, otherwise M0 will still work but
40
# the results will be unreliable.
41
#
42
# Parameter "correctForPhaseContainment" specifies whether
43
# a correction should be made for incomplete HPD signal collection
44
# inside the summed time slices, and "correctionPhaseNS" specifies
45
# the delay (in ns) of the HPD signal w.r.t. the ADC digitization
46
# clock edge. That is, in the reco code, increasing correctionPhaseNS
47
# moves reco window to the left w.r.t. the signal (AFAIK, the behavior
48
# of PhaseDelay QIE11 configuration register is the opposite).
49
#
50
m0Parameters = cms.PSet(
51
firstSampleShift = cms.int32(0),
52
samplesToAdd = cms.int32(2),
53
correctForPhaseContainment = cms.bool(
True
),
54
correctionPhaseNS = cms.double(6.0),
55
)
Generated for CMSSW Reference Manual by
1.8.16