CMS 3D CMS Logo

MonitorAlCaEcalPi0_cfi.py
Go to the documentation of this file.
1 import FWCore.ParameterSet.Config as cms
2 
3 from DQMServices.Core.DQMEDAnalyzer import DQMEDAnalyzer
4 EcalPi0MonDQM = DQMEDAnalyzer('DQMSourcePi0',
5  prescaleFactor = cms.untracked.int32(1),
6  FolderName = cms.untracked.string('AlCaReco/EcalPi0'),
7 
8  AlCaStreamEBpi0Tag = cms.untracked.InputTag("hltAlCaPi0RegRecHits","pi0EcalRecHitsEB"),
9  AlCaStreamEEpi0Tag = cms.untracked.InputTag("hltAlCaPi0RegRecHits","pi0EcalRecHitsEE"),
10  AlCaStreamEBetaTag = cms.untracked.InputTag("hltAlCaEtaRegRecHits","etaEcalRecHitsEB"),
11  AlCaStreamEEetaTag = cms.untracked.InputTag("hltAlCaEtaRegRecHits","etaEcalRecHitsEE"),
12 
13  isMonEEpi0 = cms.untracked.bool(True),
14  isMonEBpi0 = cms.untracked.bool(True),
15  isMonEEeta = cms.untracked.bool(True),
16  isMonEBeta = cms.untracked.bool(True),
17 
18 
19  SaveToFile = cms.untracked.bool(False),
20  FileName = cms.untracked.string('MonitorAlCaEcalPi0.root'),
21 
22  clusSeedThr = cms.double( 0.5 ),
23  clusSeedThrEndCap = cms.double( 1.0 ),
24  clusEtaSize = cms.int32( 3 ),
25  clusPhiSize = cms.int32( 3 ),
26  seleXtalMinEnergy = cms.double( -0.15 ),
27  seleXtalMinEnergyEndCap = cms.double( -0.75 ),
28  selePtGamma = cms.double(1 ),
29  selePtPi0 = cms.double( 2. ),
30  seleMinvMaxPi0 = cms.double( 0.22 ),
31  seleMinvMinPi0 = cms.double( 0.06 ),
32  seleS4S9Gamma = cms.double( 0.83 ),
33  selePi0Iso = cms.double( 0.5 ),
34  ptMinForIsolation = cms.double( 1 ),
35  selePi0BeltDR = cms.double( 0.2 ),
36  selePi0BeltDeta = cms.double( 0.05 ),
37 
38  selePtGammaEndCap = cms.double( 0.8 ),
39  selePtPi0EndCap = cms.double( 3.0 ),
40  seleS4S9GammaEndCap = cms.double( 0.9 ),
41  seleMinvMaxPi0EndCap = cms.double( 0.3 ),
42  seleMinvMinPi0EndCap = cms.double( 0.05 ),
43  ptMinForIsolationEndCap = cms.double( 0.5 ),
44  selePi0IsoEndCap = cms.double( 0.5 ),
45  selePi0BeltDREndCap = cms.double( 0.2 ),
46  selePi0BeltDetaEndCap = cms.double( 0.05 ),
47 
48  selePtGammaEta = cms.double(1.2),
49  selePtEta = cms.double(4.0),
50  seleS4S9GammaEta = cms.double(0.9),
51  seleS9S25GammaEta = cms.double(0.8),
52  seleMinvMaxEta = cms.double(0.8),
53  seleMinvMinEta = cms.double(0.3),
54  ptMinForIsolationEta = cms.double(1.0),
55  seleEtaIso = cms.double(0.5),
56  seleEtaBeltDR = cms.double(0.3),
57  seleEtaBeltDeta = cms.double(0.1),
58  massLowPi0Cand = cms.double(0.104),
59  massHighPi0Cand = cms.double(0.163),
60 
61  selePtGammaEtaEndCap = cms.double(1.5),
62  selePtEtaEndCap = cms.double(5),
63  seleS4S9GammaEtaEndCap = cms.double(0.9),
64  seleS9S25GammaEtaEndCap = cms.double(0.85),
65  seleMinvMaxEtaEndCap = cms.double(0.8),
66  seleMinvMinEtaEndCap = cms.double(0.3),
67  ptMinForIsolationEtaEndCap = cms.double(0.5),
68  seleEtaIsoEndCap = cms.double(0.5),
69  seleEtaBeltDREndCap = cms.double(0.3),
70  seleEtaBeltDetaEndCap = cms.double(0.1),
71 
72  posCalcParameters = cms.PSet( T0_barl = cms.double(5.7),
73  T0_endc = cms.double(3.1),
74  T0_endcPresh = cms.double(1.2),
75  LogWeighted = cms.bool(True),
76  W0 = cms.double(4.2),
77  X0 = cms.double(0.89)
78  )
79 
80 
81 )
82 
83